081 014 2365 WhatsApp

Structural engineers · Centurion, Gauteng

Sign-off, reports and expert opinion on structures.

A professionally registered structural engineering practice. We certify completed building work, inspect and report on property, and give independent evidence when a structure ends up in dispute.

  • Pr Eng registered with ECSA
  • 2019 practising since
  • 5.0 from 30 Google reviews

01 — Services

Five structures, five reasons we get the call

01 / 05

Bridges & rehabilitation

Temporary works

A deck pushed out over the piers on a steel launching nose, which droops on the cantilever and lifts as it lands. None of it is the permanent structure. We design the support, access and stability systems that hold a structure up while it is being worked on, including the jacking that carries a bridge while its bearings are replaced.

For contractors, road authorities

02 / 05

Pre-purchase inspection

Property evaluation

Walls tell you what the ground underneath them has been doing, and the cracking reads from the footings up. A structural inspection and a written report of what we find: what is causing the cracking, the foundations, the roof structure, and movement related to damp or poor drainage. Know what you are buying before transfer, not after.

For buyers, sellers, estate agents

03 / 05

National Building Regulations

Form 2 & Form 4 sign-off

A portal frame shed stands on three connections: the base plate, the longitudinal tie and the eaves haunch. Somebody registered has to look at them and say so in writing. We inspect the work, steel portals or trusses at 850 mm centres alike, check it against the approved drawings and the regulations, and sign the forms your local authority is asking for.

For homeowners, builders, architects

04 / 05

Insurance & body corporate

Engineering reports

Then the array arrives. Panels land on one slope of a roof designed for sheeting, and the trusses underneath them carry load that was never in anyone’s calculation. We confirm whether the structure can take it, and document building defects so there is a proper record of the condition.

For insurers, body corporates, homeowners

05 / 05

Disputes & litigation

Expert witness

A crack in a column, and a room full of people who need to know what it means. Independent structural opinion, evidence based and clearly documented, set out so a legal team, an insurer or a court can follow the reasoning from what was observed through to what it means.

For attorneys, insurers, courts

Relentless Engineering

Every load finds its way to the ground; every opinion has to find its way into the record.

02 — Structures

What gets put in front of us

Different structures fail in different ways, and the first thing most clients want to know is whether we have seen one before. Six of the types that come across the desk.

  • 01

    Timber roof trusses

    Nail-plated trusses at 850 mm centres are sized for the roof they were built to carry. Heavier tiles, solar panels, a geyser or ducting added later load them in ways nobody calculated, so we check the members, the plated joints and the bracing.

  • 02

    Steel warehouses

    Portal frames, purlins and bracing. Base plates, eaves haunches and the ties that are often missing.

  • 03

    Property inspections

    Residential, commercial and industrial property. Cracking, foundations, roof structure and movement, inspected on site and set out in a written report.

  • 04

    Bridge piers and bearings

    Headstocks, bearings and the jacking arrangement that holds the deck while they come out.

  • 05

    Lattice pylons and masts

    Bolted steel lattice under wind. Leg loads, bracing panels and the condition of the connections.

  • 06

    Retaining walls

    Stems, bases and counterforts, subsoil drainage and weepholes, and the cracking that says the drainage failed.

03 — Analysis

This runs behind every certificate

A roof truss from a real assessment, solving in your browser as the load builds. Watch the members change colour as the force in them reverses, and the frame settle under a solar array it was never designed to carry.

  • Roof load0.00kN/m
  • Max compression0.00kN
  • Max tension0.00kN
  • Deflection0.00mm

7.50 m span · 38 × 114 mm SA pine · trusses at 850 mm centres. The figures are solved live by direct stiffness, not animated from a recording. An illustrative model rather than a design.

5.0from 30 Google reviews

Client reviews

Read them on Google
  • “He provided me with a quote the same day I reached out to him. I received a report in timely fashion that is easily understandable but still highly professional.”
  • “Contacted SI for a post solar installation roof load inspection. Pren is extremely responsive, on time for the appointment, communication is excellent.”
  • “Having strangers go through your home is uncomfortable, BUT not this company… and the service is fast. I HIGHLY RECOMMEND THEM”
  • “Thank you for assisting us on such short notice with the inspection. The report you provided us was well structured and insightful. I would recommend Structures Initiate to anyone.”
  • “The inspection was conducted thoroughly and professionally, with great attention to detail. The engineer communicated findings clearly, answered questions patiently.”
  • “Structures Initiate delivered professional, high quality service with excellent client engagement and attention to detail and timelines.”

04 — Work

Recent work

A sample of recent instructions. Clients and addresses are not named, so each is described by area and scope.

Inside the roof space of a factory, with red steel roof trusses overhead and insulated ducts and pipes on the mezzanine below.

Solar approval

Solar loading on industrial steel roof

Lanseria, Gauteng · 2026

A multi-storey industrial factory with a walk-on mezzanine below the roof. The roof is about 4,300 m² of steel Pratt trusses pitched at about 7.5°, spanning 43.94 m at 9.8 m centres. We carried out the field inspection, measured the roof on site and modelled it in 3D. We then completed a structural analysis for compliance of the proposed solar loading.

Restaurant premises in a shopping centre, where cracking appeared during demolition work by a neighbouring tenant.

Insurance claim

Cracking in commercial property

Blue Hills, Midrand

Structural assessment in support of an insurance claim, after cracking appeared through wall finishes and tiling within two to three minutes of demolition work by a neighbouring tenant. Horizontal cracking at a consistent level across separate rooms, tiles cracked through their full thickness, and no evidence of settlement or progressive structural failure. Attributed to a transient disturbance affecting the building.

Steel roof structure with trusses, columns and purlins over a single-storey building nearing completion.

Form 2 & Form 4

Roof rehabilitation in commercial property

Noordwyk, Midrand

Visual assessment of the roof trusses, column supports and purlin configuration, to document the findings and sign off Form 4. Three deficiencies were identified, at the column to floor connection, in the absence of longitudinal ties, and at the column to truss connection, each with the structural modification required to resolve it.

Expert witness

Engineering opinion in a tax dispute

Opinion and evidence · High Court, Johannesburg · 2026

Independent opinion on whether roads, water pipelines, fencing, irrigation systems, topsoil and landscaping constitute a “building” for the purposes of section 13quin of the Income Tax Act 58 of 1962. The opinion set out what makes a structure a building in engineering terms, being a permanently founded system with a continuous load path designed to resist imposed actions, and concluded that the asset categories in question are civil and site infrastructure works, distinct from building structures.

Timber roof structure seen from inside the roof space, beneath the original corrugated sheeting.

Solar approval

Steel roof sheeting on timber trusses

Auckland Park, Johannesburg

Assessment of existing timber roof structures for a proposed roof mounted PV system, requested by the solar contractor before installation. The roofs had been designed for lightweight corrugated sheeting and later re-covered with heavier clay tiles, with no evidence of strengthening at the time. The calculations addressed that change in dead load before the question of the panels was reached.

Typical section through the reinforced concrete retaining wall, with the brick facing, subsoil drainage and weephole detail.

Design and documentation

Substation boundary retaining wall

Alberton, Gauteng

Design and detailing of a reinforced concrete retaining wall varying from 500 mm to 1 500 mm in height, faced in brickwork and tied through with galvanised butterfly ties at a minimum of four per m². Subsoil drainage with 75 mm weepholes at 2.5 m centres, expansion joints at no more than 10 m, and a bar schedule complying with SANS 282:2011.

Two first-floor cantilever walkways of a face-brick residential complex, with white balustrades, brown downpipes and garage doors below.

Engineering report

Cantilever slabs in a residential complex

Brummeria, Pretoria · 2026

Condition assessment of the first-floor cantilever slabs of a residential complex more than 30 years old, ahead of the owners’ annual meeting. Spalling concrete, corroding reinforcement and diagonal cracks in the brickwork above. With no drawings and no drip groove on the slab edges, the report traced the corrosion to water tracking back under the slabs, and judged the wall cracking most probably the result of slender slabs deflecting under the brickwork, not foundation settlement. Repairs were set out in three phases, unsafe concrete first.

Cracking running from the coping down through a rendered masonry infill panel between the boundary wall's columns.

Remedial design

Cracks on boundary retaining wall

Irene, Pretoria

Inspection of a boundary wall retaining soil off the neighbouring property, after cracking appeared through the masonry infill panels between its columns. Rather than rebuild, additional reinforced concrete columns on engineered foundations were specified between the existing ones, reducing the effective panel span from 3.45 m to about 1.7 m and with it the bending stress in the panels.

05 — Process

How an instruction runs

Three steps, whether it is a single geyser certificate, a condition assessment or an expert opinion.

  1. STEP 01

    Call, WhatsApp or email

    Tell us what you need and where the property is. We will say up front whether it is something we do, what it involves, and what it will cost.

  2. STEP 02

    Site inspection

    We attend site, inspect and measure what actually matters to the question you have asked, and photograph the evidence for the record.

  3. STEP 03

    Certificate or report

    You get the signed certificate, or the written report setting out what we found, the basis for it, and what we recommend you do about it.

06 — About

Relentless engineering

Structures Initiate (Pty) Ltd was founded in 2019 by Pren Moodley, a structural engineer with close to fifteen years in the field.

He holds a BSc in Civil Engineering from the University of the Witwatersrand, is registered as a Professional Engineer with the Engineering Council of South Africa, and is a member of the South African Institution of Civil Engineering.

The practice works out of Centurion and takes on structural work across Gauteng, from a single roof certificate for a homeowner through to expert opinion in a dispute.

His temporary works and bridge experience, including jacking arrangements for bearing replacement, was gained in previous practice rather than under Structures Initiate. The practice offers that work; the track record behind it belongs to the engineer rather than to the company.

Every report and certificate is signedPren Moodley (BSc Eng, MSAICE, Pr Eng)

07 — Contact

Talk to an engineer

Phone or WhatsApp is quickest. If it is easier to write it down, the form reaches the same inbox.

Telephone & WhatsApp
081 014 2365
Office
Corporate 66 Office Park
269 Von Willich Avenue
Die Hoewes, Centurion, 0163

Your details go straight to our inbox.